Contactors: Motor Control, Lighting, HVAC,
Power, 3 or 4 pole. Efficient New
Streamline, Smaller, Low Power Drain, Low
Noise, Easy to Install.
50
Amp. AC-1, 32 Amp. AC-3 3
Pole Normally Open (N.O.)
contacts 600V 50A.
Incandescent, LED or resistive load 32A. Motor control, 20HP@
480VAC Auxiliary contact 1NO/1NC
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC
Details
Specifications
60 Amp. 4 Pole
(Silent Operation)
Normally
Open (N.O.) contacts
For 120/220/277/Rated 500V,
10 HP
@240V, 20HP @460V
40A. Ballast, 12KW@ 220VAC
Dimension: 2.2w x 3.3h x 2.5d inch
63Amp AC-1, 40Amp AC-3
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC
(Silent Operation,
Less than 7 dBA)
.
934040
4 0
Amp. 4 Pole
(Silent Operation,
less than 7dBA)
Normally
Open (N.O.) contacts
Rated UI 400V,
Ith 500V
7.5HP @240V, 15HP @460V
40A. Ballast, 7 KW@ 220VAC
Dimension: 2.2w x 3.3h x 2.5d inch
40Amp AC-1, 30Amp AC-3
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC
Specifications
add DIN rail
934004
40Amp.
4 Pole N/C (Silent Operation)
Normally closed (N.C.) contacts
Rated UI 400V,
Ith 500V 40A. Incandescent or resistive load AC1 32A. Ballast and General purpose AC3
Power
indicator, DIN mount Dim: 2.2 x 3.5 x 2.5 in
(55 x 90 x 70 mm)
Power Lug Terminal Capacity AWG # 4
Specifications
934060
60 Amp. 4 Pole
(Silent Operation)
Normally
Open (N.O.) contacts
Rated UI 400V,
Ith 500V
10 HP
@240V, 20HP @460V
40A. Ballast, 12KW@ 220VAC
Dimension: 2.2w x 3.3h x 2.5d inch
63Amp AC-1, 40Amp AC-3
Power Lug Terminal Capacity AWG # 4
Coil 110/120VAC
Specifications
add DIN rail
934006
60 Amp. 4 Pole
(Silent Operation)
Normally closed (N.C.) contacts
Rated
UI 400V,
Ith 500V 40A. Ballast, 7 KW@ 220VAC 63A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 2.2 x 3.5 x 2.5 in (55 x 90 x 70 mm)
Power Lug Terminal Capacity AWG # 4
120VAC coil
Specifications
dpcontactor
40 Amp. 4 Pole
944120
Normally Open
(N.O.) contacts
NEMA 2 Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 2
120VAC coil
SPECIFICATIONS
Dimensions
40 Amp.
3 Pole 943120
Normally Open
(N.O.) contacts
NEMA 2 Definite purpose
10HP @240V, 15KW 277VAC
40 A. Ballast, 7 KW@ 220VAC
50A AC-1, 40A. AC-3 600V
Lighting - Refrigeration - HVAC
Dim: 2.75 x 3.5 x 3.0 in (70 x 90 x
75 mm)
Power Lug Terminal Capacity AWG # 4
120VAC coil
10 0 Amp. 4 Pole
Slim contactor
Normally
Open (N.O.) contacts Rated
UI 400V,
Ith 500V 50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 110 x 81 x 68 mm)
Dimensions
Power Lug Terminal Capacity AWG # 2/0
120VAC coil
OUT OF STOCK
10 0 Amp. 4 Pole
Slim
contactor
Normally closed (N.C.) contacts
Rated
UI 400V,
Ith 500V 50A. Ballast, 10 KW@ 220VAC, 15KW@277V 100A AC-1, 40A. AC-3 40A, 24VDC, DC Switching Power
indicator, DIN mount
Dim: 110 x 81 x 68 mm)
Dimensions
Power Lug Terminal Capacity AWG # 2/0
120VAC coil
933021
Miniature Contactor
20Amp, 3 Pole,
120VAC Coil
2 HP
@240V, 7.5HP @460V
1HP @120V, 20Amp AC-1, 12Amp. AC-3
Screw Clamp Terminals, 600V, 1 N.O. Aux.,
AC Coil Current Inrush 32VA,
Sealed 6VA
Dim: 1.7 x 2.5 x 2.3 in
(45 x 64 x 58 mm)
Power Lug Terminal Capacity AWG # 8
933020
Miniature Contactor
20Amp, 3 Pole,
12VDC Coil
2 HP
@240V, 7.5HP @460V
1HP @120V, 20Amp AC-1, 12Amp. AC-3 Screw Clamp Terminals, 600V, 1 N.O. Aux., DC Coil Current Inrush/Sealed 250mA
Dim: 1.7 x 2.5 x 2.3 in
(45 x 64 x 58 mm)
Power Lug Terminal Capacity AWG # 8
Specifications
Transformer 50VA
480/277/240/208VAC To 120VAC
SPECIFICATIONS
DIN rail 20cm (7.87inch)
Vacuum contactor
35, 60, 100A
Silent , No acoustical
sound, No click, No
vibration
Single pole
3 pole
Lighting Contactor Contactor
NO-NC
Contactor guide
Solid State 3 Pole Contactor
Solid State Single Pole
Contactor
Latching Relays
Solid State Kit
Dist 2024
Grainger Graybar
ABBDepot