Contactor
  
 


30A 3Pole


63A 4Pole


63A 4Pole AX


50A 4Pole DP


100 AMP LIGHTING CONTACTOR 4 Pole 120V Coil   (Silent Operation)
 








 

 

100 Amp.  4 Pole  
NORMALLY OPEN  --]  [--

 Normally Open (N.O.) contacts
 For 120/220/277/Rated 500V,
 10HP @240V, 30HP @460V
 60A. Ballast, 15 KW@ 220VAC
 100Amp AC-1,  60Amp AC-3
Coil: Inrush 106VA, Sealed 22VA
Certified CE, EN, IEC 61095.  Not UL listed
Power Lug Terminal Capacity AWG # 2/0
Coil 110/120VAC  Add DIN rail
Dimensions

934100  N/O  

 120VAC    $199.99   

 



Contactor 934100A  N/O
with  Auxiliary Contact 

1 NC  1 NO,  Rated 5 Amp, Pilot Duty Class 2

 120VAC    $249.99   

   

100 Amp.  4 Pole  
NORMALLY
CLOSED   --] /[--
 
Normally Close (N.C.) contacts
 For 120/220/277/Rated 500V,
 10HP @240V, 30HP @460V
 60A. Ballast, 15 KW@ 220VAC
 100Amp AC-1,  60Amp AC-3
Coil: Inrush 106VA, Sealed 22VA
Certified
CE, EN, IEC 61095.  Not UL listed
Power Lug Terminal Capacity AWG # 2/0
Coil 110/120VAC   Add DIN rail

Dimensions

934101  N/C 

 120VAC    $299.99   

 



Contactor 934101A N/C
with  Auxiliary Contact 

1 NC  1 NO,  Rated 5 Amp, Pilot Duty Class 2

 120VAC    $349.99   

 934100
SPECIFICATIONS  

range of product

Modular iec

product identification

934100

product or component type

Contactor

device short name

HC1-100

device application

Heating-low inductive load

Poles

4P

[Ie] rated operational current

100 A AC-7A

pole contact composition

4 NO

network type

AC

utilization category

AC-1 conforming to EN 60947-4-1
AC-7A conforming to EN 61095
AC-7A conforming to UTE C 61-481

control type

Wired Remote control

[Uc] control circuit voltage

Selection 110.. 120 /220...240 V AC 50/60 Hz

Main

 

network frequency

50/60 Hz

[Ue] rated operational voltage

400 V AC 50/60 Hz

Ie maximum current

AC-1: 100A  at 400 V AC 50/60 Hz

[Ui] rated insulation voltage

500 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage

4 kV

control signal type

Maintained

switching frequency

100 switching operations/day

local signaling

Action indicator

hold-in power consumption in VA

22 VA

inrush power in VA

106 VA

mounting mode

Clip-on

mounting support

35 mm symmetrical DIN rail

dimensions

Dimensions

height

85 mm

width

108 mm

depth

60 mm

color

White

electrical durability

30000 cycles IEC 61095 400 V AC 50 Hz AC-7A

connections - terminals

Control circuit:   terminals2 cable(s) 1.5 mm² rigid
Control circuit:  terminals1 cable(s) 1.5…2.5 mm² rigid
Control circuit:  terminals2 cable(s) 1.5…2.5 mm² flexible
Power circuit:  terminals1 cable(s) 6…35 mm² solid or flexible

tightening torque

Power circuit: 3.5 N.m
Control circuit: 0.8 N.m A1 / A2

product compatibility

934002 auxiliary contact  no/nc
ICTs schneider
5TT siemens

 

 

standards

EN 61095
IEC 61095
UTE C 61-481

noise level

30 dB

heat dissipation

4.2 W at 50/60 Hz

IP degree of protection

IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529

pollution degree

2

tropicalisation

2 conforming to EN 60947-4-1

relative humidity

95 % at 55 °C

operating altitude

2000 m

operation air temperature

-5…60 °C

ambient air temperature for storage

-40…70 °C

 

 

 

 
     Copyright © Electrodepot. All rights reserved