Operating
Voltage: 12 to 15.o VDC Operating
Temperature: -4° to +140° F (-20° to +60° C) Receiver Type:
Digital Superheterodyne Sensitivity: -118
dB (minimum), Selectivity: 6
KHz Carrier
Frequency: 27,255 MHz Number of Codes:
65,536 Code Setting
Method: DIP switch programming Data Input:
Alarm, restore, status, and low battery Dimensions:
7.9 in L x 1.25 in W x 6.5 in H (201 x 32 x 165
mm) Weight: 1.5 lb.
(0.680 Kg) Current Drain:
-300
mA, typical standby 65 mA alarm @ 12 VDC
Outputs: Alarm - form "C" relay per channel
Low Battery - one open collector output per receiver
(Audio and signal strength test points)
Not
included
Antenna Impedance: 50 Ohms Required,
Selection: Whip
Antenna 2 Miles of Line-of-Sight range
Up to 10 Miles with
Long Range Antenna
|